| System does not work automatically
|
1. Circuit breaker may
be tripped
2. Reservoir may be low or empty |
1. Check your breaker
2. Refill with Py-Tech (Pyrethrum Insecticide) |
| Motor labors during operation
(cuts on/off) |
1. Operating pressure
set too high
2. Suction filter may be clogged
|
1. Adjust pressure (150-160
psi).
Never set above 175 psi
2. Clean or replace suction filter
|
| All nozzles drip or spew
during startup & shutdown (there is a delay between when
the motor turns on and nozzles spray) |
1. Air in tubing line
to nozzles
2. Used a strong chemical that has
damaged system O-Rings |
1. Bleed air. If problem persists call
for help 1-800-776-5005
2. Use only Py-Tech
|
| Spray system does not
register ample pressure (150 psi) |
1. Suction filter may
be clogged
2. Check valve may be clogged
3. Pump may be damaged
4. Pressure gauge may be faulty
|
1. Clean or replace
2. Clean or replace
3. Replace pump
4. Replace gauge
|
| Some nozzles do not spray
as good as others0 |
1. Nozzle filters or internal
parts may
be clogged |
1. Clean or replace spray
tip only
|
NOTE:
| Pro-Techs insecticide
and odor control solutions are specially formulated for
Pro-Techs spraying systems with safety and performance
in mind. They will not damage the seals and o-rings found
throughout the pump, valves and spray nozzles. Nor will
they separate out of solution in the reservoir and tubing.
Therefore, you will receive optimum performance with no
nozzle clog. Using solutions other than Pro-Techs
voids your warranty. |
|